FD

fda-consultant-specialist

Regulatory consulting service for FDA compliance, submissions, and medical device cybersecurity.

Install

mkdir -p .claude/skills/fda-consultant-specialist && curl -L -o skill.zip "https://agentskills.codes/api/skills/download/2083" && unzip -o skill.zip -d .claude/skills/fda-consultant-specialist && rm skill.zip

Installs to .claude/skills/fda-consultant-specialist

Activation

This is the description your AI agent reads to decide when to run this skill — the better it matches your request, the more reliably it fires.

FDA regulatory consultant for medical device companies. Provides 510(k)/PMA/De Novo pathway guidance, QMSR (21 CFR 820, which incorporates ISO 13485:2016 by reference since 2026-02-02; formerly QSR) compliance, HIPAA assessments, and device cybersecurity. Use when user mentions FDA submission, 510(k), PMA, De Novo, QMSR, QSR, ISO 13485 for FDA, premarket, predicate device, substantial equivalence, HIPAA medical device, or FDA cybersecurity.
444 chars✓ has a “when” triggerlonger than Claude Code's old 250-char listing cap (fine on current versions)
Advanced

Key capabilities

  • Determine appropriate FDA regulatory pathways
  • Manage 510(k) submission documentation
  • Assess QMSR and ISO 13485 compliance
  • Conduct HIPAA security risk assessments
  • Evaluate medical device cybersecurity controls

How it works

The consultant maps device characteristics against FDA regulatory frameworks, guiding the user through submission pathways, quality system requirements, and mandatory cybersecurity and privacy safeguards.

Inputs & outputs

You give it
Device technical documentation and intended use
You get back
Regulatory submission strategy or compliance gap analysis

When to use fda-consultant-specialist

  • Preparing 510(k) or PMA submissions
  • Conducting QSR compliance assessments
  • Reviewing medical device cybersecurity
  • Navigating FDA regulatory pathways

About this skill

FDA Consultant Specialist

FDA regulatory consulting for medical device manufacturers covering submission pathways, the Quality Management System Regulation (QMSR, 21 CFR Part 820 — formerly the QSR), HIPAA compliance, and device cybersecurity requirements.

Table of Contents


FDA Pathway Selection

Determine the appropriate FDA regulatory pathway based on device classification and predicate availability.

Decision Framework

Predicate device exists?
├── YES → Substantially equivalent?
│   ├── YES → 510(k) Pathway
│   │   ├── No design changes → Abbreviated 510(k)
│   │   ├── Manufacturing only → Special 510(k)
│   │   └── Design/performance → Traditional 510(k)
│   └── NO → PMA or De Novo
└── NO → Novel device?
    ├── Low-to-moderate risk → De Novo
    └── High risk (Class III) → PMA

Pathway Comparison

PathwayWhen to UseTimelineUser Fee (FY2024)
510(k) TraditionalPredicate exists, design changes90 days$21,760 (FY2024)
510(k) SpecialManufacturing changes only30 days$21,760 (FY2024)
510(k) AbbreviatedGuidance/standard conformance30 days$21,760 (FY2024)
De NovoNovel, low-moderate risk150 days$134,676 (FY2024)
PMAClass III, no predicate180+ days$425,000+ (FY2024)

User fees are set annually under MDUFA. Verify current-fiscal-year fees at fda.gov (MDUFA user fee schedule) before budgeting; small-business rates differ.

Pre-Submission Strategy

  1. Identify product code and classification
  2. Search 510(k) database for predicates
  3. Assess substantial equivalence feasibility
  4. Prepare Q-Sub questions for FDA
  5. Schedule Pre-Sub meeting if needed

Reference: See fda_submission_guide.md for pathway decision matrices and submission requirements.


510(k) Submission Process

Workflow

Phase 1: Planning
├── Step 1: Identify predicate device(s)
├── Step 2: Compare intended use and technology
├── Step 3: Determine testing requirements
└── Checkpoint: SE argument feasible?

Phase 2: Preparation
├── Step 4: Complete performance testing
├── Step 5: Prepare device description
├── Step 6: Document SE comparison
├── Step 7: Finalize labeling
└── Checkpoint: All required sections complete?

Phase 3: Submission
├── Step 8: Assemble submission package
├── Step 9: Submit via eSTAR
├── Step 10: Track acknowledgment
└── Checkpoint: Submission accepted?

Phase 4: Review
├── Step 11: Monitor review status
├── Step 12: Respond to AI requests
├── Step 13: Receive decision
└── Verification: SE letter received?

Required Sections (21 CFR 807.87)

SectionContent
Cover LetterSubmission type, device ID, contact info
Form 3514CDRH premarket review cover sheet
Device DescriptionPhysical description, principles of operation
Indications for UseForm 3881, patient population, use environment
SE ComparisonSide-by-side comparison with predicate
Performance TestingBench, biocompatibility, electrical safety
Software DocumentationLevel of concern, hazard analysis (IEC 62304)
LabelingIFU, package labels, warnings
510(k) SummaryPublic summary of submission

Common RTA Issues

IssuePrevention
Missing user feeVerify payment before submission
Incomplete Form 3514Review all fields, ensure signature
No predicate identifiedConfirm K-number in FDA database
Inadequate SE comparisonAddress all technological characteristics

QMSR Compliance (formerly QSR)

Quality Management System Regulation (QMSR) requirements for medical device manufacturers under 21 CFR Part 820.

QMSR transition (effective 2026-02-02): FDA's QMSR final rule (89 FR 7496) amended 21 CFR Part 820 to incorporate ISO 13485:2016 by reference and removed the legacy QSR subsection structure (820.20–820.198). Those subsection numbers are historical and no longer exist in the CFR; the corresponding requirements now flow from ISO 13485:2016 clauses plus the retained/renumbered sections 820.10 (requirements, incl. the ISO 13485 incorporation), 820.35 (records), and 820.45 (device labeling and packaging controls). 21 CFR Parts 801, 803, 806, and 830 are unchanged. Legacy QSR numbers below are kept only as a familiar index, each mapped to its current ISO 13485 clause.

Key Quality Subsystems (legacy QSR index → current ISO 13485:2016 clause)

Legacy QSR Section (historical, pre-2026)TitleCurrent authority under QMSRFocus
820.20Management ResponsibilityISO 13485 §5.1, 5.5, 5.6Quality policy, org structure, management review
820.30Design ControlsISO 13485 §7.3Input, output, review, verification, validation
820.40Document ControlsISO 13485 §4.2.4Approval, distribution, change control
820.50Purchasing ControlsISO 13485 §7.4Supplier qualification, purchasing data
820.70Production ControlsISO 13485 §6.3, 6.4, 7.5Process validation, environmental controls
820.100CAPAISO 13485 §8.5.2, 8.5.3Root cause analysis, corrective actions
820.181Device Master RecordISO 13485 §4.2.3 (medical device file) + 21 CFR 820.35Specifications, procedures, acceptance criteria

Design Controls Workflow (ISO 13485 §7.3; legacy QSR 820.30)

Step 1: Design Input
└── Capture user needs, intended use, regulatory requirements
    Verification: Inputs reviewed and approved?

Step 2: Design Output
└── Create specifications, drawings, software architecture
    Verification: Outputs traceable to inputs?

Step 3: Design Review
└── Conduct reviews at each phase milestone
    Verification: Review records with signatures?

Step 4: Design Verification
└── Perform testing against specifications
    Verification: All tests pass acceptance criteria?

Step 5: Design Validation
└── Confirm device meets user needs in actual use conditions
    Verification: Validation report approved?

Step 6: Design Transfer
└── Release to production with DMR complete
    Verification: Transfer checklist complete?

CAPA Process (ISO 13485 §8.5.2/8.5.3; legacy QSR 820.100)

  1. Identify: Document nonconformity or potential problem
  2. Investigate: Perform root cause analysis (5 Whys, Fishbone)
  3. Plan: Define corrective/preventive actions
  4. Implement: Execute actions, update documentation
  5. Verify: Confirm implementation complete
  6. Effectiveness: Monitor for recurrence (30-90 days)
  7. Close: Management approval and closure

Reference: See qsr_compliance_requirements.md for the historical QSR structure with full QMSR/ISO 13485:2016 clause mapping.


HIPAA for Medical Devices

HIPAA requirements for devices that create, store, transmit, or access Protected Health Information (PHI).

Applicability

Device TypeHIPAA Applies
Standalone diagnostic (no data transmission)No
Connected device transmitting patient dataYes
Device with EHR integrationYes
SaMD storing patient informationYes
Wellness app (no diagnosis)Only if stores PHI

Required Safeguards

Administrative (§164.308)
├── Security officer designation
├── Risk analysis and management
├── Workforce training
├── Incident response procedures
└── Business associate agreements

Physical (§164.310)
├── Facility access controls
├── Workstation security
└── Device disposal procedures

Technical (§164.312)
├── Access control (unique IDs, auto-logoff)
├── Audit controls (logging)
├── Integrity controls (checksums, hashes)
├── Authentication (MFA recommended)
└── Transmission security (TLS 1.2+)

Risk Assessment Steps

  1. Inventory all systems handling ePHI
  2. Document data flows (collection, storage, transmission)
  3. Identify threats and vulnerabilities
  4. Assess likelihood and impact
  5. Determine risk levels
  6. Implement controls
  7. Document residual risk

Reference: See hipaa_compliance_framework.md for implementation checklists and BAA templates.


Device Cybersecurity

FDA cybersecurity requirements for connected medical devices.

Premarket Requirements

ElementDescription
Threat ModelSTRIDE analysis, attack trees, trust boundaries
Security ControlsAuthentication, encryption, access control
SBOMSoftware Bill of Materials (CycloneDX or SPDX)
Security TestingPenetration testing, vulnerability scanning
Vulnerability PlanDisclosure process, patch management

Device Tier Classification

Tier 1 (Higher Risk):

  • Connects to network/internet
  • Cybersecurity incident could cause patient harm

Tier 2 (Standard Risk):

  • All other connected devices

Postmarket Obligations

  1. Monitor NVD and ICS-CERT for vulnerabilities
  2. Assess applicability to device components
  3. Develop and test patches
  4. Communicate with customers
  5. Report to FDA per guidance

Coordinated Vulnerability Disclosure

Researcher Report
    ↓
Acknowledgment (48 hours)
    ↓
Initial Assessment (5 days)
    ↓
Fix Development
    ↓
Coordinated Public Disclosure

Reference: See device_cybersecurity_guidance.md for SBOM format examples and threat modeling templates.


Resources

scripts/

ScriptPurpose
fda_submission_tracker.pyTrack 510(

Content truncated.

When not to use it

  • When the device is not classified as a medical device
  • When seeking legal advice rather than regulatory guidance

Prerequisites

Device classification informationPredicate device identification

Limitations

  • Regulatory requirements vary significantly by device class
  • Consultation does not replace formal FDA review or legal counsel

How it compares

This provides specialized regulatory navigation for medical technology rather than general business or software consulting.

Compared to similar skills

fda-consultant-specialist side by side with the closest alternatives in the catalog.

SkillInstallsUpdatedSafetyDifficulty
fda-consultant-specialist (this skill)22moReviewAdvanced
legal-risk-assessment36moNo flagsIntermediate
mdr-745-specialist22moReviewAdvanced
lex03moReviewAdvanced

Try saying

Example prompts that trigger this skill in your AI assistant.

More by alirezarezvani

View all by alirezarezvani

ma-playbook

alirezarezvani

M&A strategy for acquiring companies or being acquired. Due diligence, valuation, integration, and deal structure. Use when evaluating acquisitions, preparing for acquisition, M&A due diligence, integration planning, or deal negotiation.

39122

ad-creative

alirezarezvani

When the user needs to generate, iterate, or scale ad creative for paid advertising. Use when they say 'write ad copy,' 'generate headlines,' 'create ad variations,' 'bulk creative,' 'iterate on ads,' 'ad copy validation,' 'RSA headlines,' 'Meta ad copy,' 'LinkedIn ad,' or 'creative testing.' This is pure creative production — distinct from paid-ads (campaign strategy). Use ad-creative when you need the copy, not the campaign plan.

3395

content-trend-researcher

alirezarezvani

Advanced content and topic research skill that analyzes trends across Google Analytics, Google Trends, Substack, Medium, Reddit, LinkedIn, X, blogs, podcasts, and YouTube to generate data-driven article outlines based on user intent analysis

30126

cold-email

alirezarezvani

When the user wants to write, improve, or build a sequence of B2B cold outreach emails to prospects who haven't asked to hear from them. Use when the user mentions 'cold email,' 'cold outreach,' 'prospecting emails,' 'SDR emails,' 'sales emails,' 'first touch email,' 'follow-up sequence,' or 'email prospecting.' Also use when they share an email draft that sounds too sales-y and needs to be humanized. Distinct from email-sequence (lifecycle/nurture to opted-in subscribers) — this is unsolicited outreach to new prospects. NOT for lifecycle emails, newsletters, or drip campaigns (use email-sequence).

2971

content-humanizer

alirezarezvani

Makes AI-generated content sound genuinely human — not just cleaned up, but alive. Use when content feels robotic, uses too many AI clichés, lacks personality, or reads like it was written by committee. Triggers: 'this sounds like AI', 'make it more human', 'add personality', 'it feels generic', 'sounds robotic', 'fix AI writing', 'inject our voice'. NOT for initial content creation (use content-production). NOT for SEO optimization (use content-production Mode 3).

2251

aws-solution-architect

alirezarezvani

Design AWS architectures for startups using serverless patterns and IaC templates. Use when asked to design serverless architecture, create CloudFormation templates, optimize AWS costs, set up CI/CD pipelines, or migrate to AWS. Covers Lambda, API Gateway, DynamoDB, ECS, Aurora, and cost optimization.

2047

You might also like

Search skills

Search the agent skills registry